Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Kidney360 ; 5(4): 618-630, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38414130

RESUMEN

Kidney diseases, both acute and chronic, are a substantial burden on individual and public health, and they continue to increase in frequency. Despite this and an intense focus on the study of disease mechanisms, few new therapeutic approaches have extended to the clinic. This is in part due to poor pharmacology of many, if not most, therapeutics with respect to the sites of kidney disease within the glomerulus or nephron. Considering this, within the past decade, and more pointedly over the past 2 years, there have been substantial developments in nanoparticle systems to deliver therapeutics to the sites of kidney disease. Here, we provide a broad overview of the various classes of nanomaterials that have been developed to improve therapeutic development for kidney diseases, the strategy used to provide kidney accumulation, and briefly the disease models they focused on, if any. We then focus on one specific system, polymeric mesoscale nanoparticles, which has broadly been used over 13 publications, demonstrating targeting of the tubular epithelium with 26-fold specificity compared with other organs. While there have been several nanomedicines that have advanced to the clinic in the past several decades, including mRNA-based coronavirus disease vaccines and others, none have focused on kidney diseases specifically. In total, we are confident that the rapid advancement of nanoscale-based kidney targeting and a concerted focus by clinicians, scientists, engineers, and other stakeholders will push one or more of these technologies into clinical trials over the next decade.


Asunto(s)
Enfermedades Renales , Humanos , Nanotecnología/métodos , Animales , Nefrología/métodos , Nanopartículas/uso terapéutico , Nanopartículas/química , Nanomedicina/métodos , Riñón/metabolismo , Riñón/efectos de los fármacos , Riñón/patología , Sistemas de Liberación de Medicamentos/métodos , Sistema de Administración de Fármacos con Nanopartículas
2.
Eur J Pharm Sci ; 189: 106537, 2023 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-37490974

RESUMEN

The parameters currently used for characterization of nanoparticles, such as size and zeta potential, were not able to reflect the performance of a nanocarrier in the biological environment. Therefore, more thorough in vitro characterization is required to predict their behavior in vivo, where nanoparticles acquire a new biological identity due to interactions with biomolecules. In this present study, we performed in vitro characterization in biological fluids for lipid nanocapsules (LNCs) with varying means sizes (50 nm and 100 nm), different electrical surface charges and different Poly Ethylene Glycol (PEG) compositions. Then, different methods were applied to show the impact of the protein corona formation on LNCs. Even if all formulations attached to plasmatic proteins, a higher thickness of corona and highest protein binding was observed for certain LNC50 formulations. A better knowledge of the phenomenon of protein adsorption over NPs in the plasmatic media is a cornerstone of clinical translation. In fact, after short blood circulation time, it is not the initially designed nanoparticle but the complex nanoparticle bearing its protein corona which circulates to reach its target.


Asunto(s)
Nanocápsulas , Nanopartículas , Corona de Proteínas , Nanocápsulas/química , Polietilenglicoles/química , Corona de Proteínas/química , Nanopartículas/química , Proteínas Sanguíneas
3.
J Control Release ; 351: 681-691, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36191672

RESUMEN

The present study investigated the pharmacokinetics of intact lipid nanocapsules (LNCs) after intravenous administration in rats. Six different Förster resonance energy transfer LNCs (FRET-LNCs) have been studied with 2 sizes (50 and 85 nm) and 3 coating types (none, DSPE-mPEG 2000 or stearylamine). A FRET-LNCs blood extraction method was developed to retain an accurate FRET signal. Intact FRET-LNCs were specifically quantified through combination of FRET signal and Nano Tracker Analysis. Pharmacokinetic data were first described by non-compartmental analysis, then used to develop a population pharmacokinetic model. The pharmacokinetic elimination of FRET-LNCs was non-linear and dependent on size and surface modification, while the distribution was dependent on size. The LNCs 85 nm volume of distribution was lower than LNCs 50 nm. As expected, LNCs 85 nm with PEG coating displayed a lower clearance than other formulations. Surprisingly, this study highlighted a faster elimination of LNCs 50 nm with PEG compared to other formulations which could be explained by instability in blood. This first pharmacokinetic model of intact LNCs allowed a thorough understanding of the influence of size and coating on pharmacokinetic properties and paves the way for future mechanistic modeling approaches to predict the fate of LNCs in vivo.


Asunto(s)
Nanocápsulas , Animales , Ratas , Transferencia Resonante de Energía de Fluorescencia/métodos , Lípidos , Composición de Medicamentos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...